{"id":1355,"date":"2026-10-09T07:55:15","date_gmt":"2026-10-09T07:55:15","guid":{"rendered":"https:\/\/wdlvalve.com\/?p=1355"},"modified":"2026-10-09T07:55:15","modified_gmt":"2026-10-09T07:55:15","slug":"absperrschieber-vs-kugelhahn","status":"publish","type":"post","link":"https:\/\/wdlvalve.com\/de\/absperrschieber-vs-kugelhahn\/","title":{"rendered":"Absperrschieber oder Kugelhahn: F\u00fcr welches Modell sollten Sie sich entscheiden?"},"content":{"rendered":"<article style=\"max-width: 920px; margin: 0 auto; color: #172033; font-family: Arial,Helvetica,sans-serif; font-size: 17px; line-height: 1.75;\">\n<header style=\"margin-bottom: 28px;\">\n<p style=\"margin: 0 0 12px; color: #536174; font-size: 14px;\">Industrial valve selection guide \u00b7 Reviewed October 2026<\/p>\n<p style=\"margin: 0 0 15px; font-size: 20px; line-height: 1.65;\"><strong>Gate valve vs ball valve<\/strong> selection depends on the required shutoff, operating speed, pressure loss, media, temperature, installation space and maintenance plan. A gate valve is often preferred for full-bore isolation in large pipelines and high-temperature service, while a ball valve is usually better when fast quarter-turn operation and tight shutoff are required.<\/p>\n<p style=\"margin: 0;\">Neither valve is automatically better. The correct choice is the design that matches the actual duty and remains operable throughout the expected service life.<\/p>\n<\/header>\n<aside style=\"margin: 24px 0; padding: 18px 20px; border-left: 5px solid #0b5fab; background: #f3f7fb;\">\n<p style=\"margin: 0 0 6px;\"><strong>Short answer<\/strong><\/p>\n<p style=\"margin: 0;\">Choose a gate valve for infrequent open-or-closed isolation where low pressure loss, large size or elevated temperature matters. Choose a ball valve for rapid operation, automation, compact installation and reliable soft-seat shutoff. Confirm pressure, temperature, materials, seat design and applicable standards before ordering either type.<\/p>\n<\/aside>\n<nav style=\"margin: 28px 0; padding: 20px; border: 1px solid #c7d2df; border-radius: 4px; background: #fff;\" aria-label=\"Article contents\">\n<p style=\"margin: 0 0 10px;\"><strong>In this guide<\/strong><\/p>\n<ul style=\"margin: 0; padding-left: 22px;\">\n<li><a style=\"color: #075da8;\" href=\"#working-principle\">How each valve works<\/a><\/li>\n<li><a style=\"color: #075da8;\" href=\"#comparison\">Gate valve vs ball valve comparison<\/a><\/li>\n<li><a style=\"color: #075da8;\" href=\"#choose-gate\">When to choose a gate valve<\/a><\/li>\n<li><a style=\"color: #075da8;\" href=\"#choose-ball\">When to choose a ball valve<\/a><\/li>\n<li><a style=\"color: #075da8;\" href=\"#service\">Media, temperature and maintenance<\/a><\/li>\n<li><a style=\"color: #075da8;\" href=\"#faq\">Frequently asked questions<\/a><\/li>\n<\/ul>\n<\/nav>\n<section id=\"working-principle\">\n<h2 style=\"margin: 34px 0 12px; font-size: 29px; line-height: 1.3; color: #101828;\">How do gate valves and ball valves work?<\/h2>\n<p style=\"margin: 0 0 15px;\">A gate valve uses a wedge or parallel gate that travels vertically across the flow path. When fully open, the gate moves out of the bore and leaves a relatively straight passage. The multi-turn stem movement makes opening slower, but the design is well suited to isolation duty and large pipeline sizes.<\/p>\n<p style=\"margin: 0;\">A ball valve uses a bored spherical closure member. Turning the stem by 90 degrees aligns the bore with the pipe or rotates the solid side of the ball across the flow. Floating and trunnion-mounted designs use different seat-loading arrangements, and both soft-seated and metal-seated configurations are available.<\/p>\n<\/section>\n<section id=\"comparison\">\n<h2 style=\"margin: 34px 0 12px; font-size: 29px; line-height: 1.3; color: #101828;\">Gate valve vs ball valve: what are the practical differences?<\/h2>\n<p style=\"margin: 0 0 16px;\">The most useful comparison is based on operating duty rather than valve appearance. The table below shows the usual tendencies; final performance depends on the specific construction, seat, pressure class, material and manufacturer design.<\/p>\n<div style=\"display: block; width: 100%; max-width: 100%; overflow-x: auto !important; -webkit-overflow-scrolling: touch; margin: 18px 0 24px; padding: 0;\" tabindex=\"0\" role=\"region\" aria-label=\"Gate valve vs ball valve comparison table\">\n<table style=\"width: 100%; min-width: 880px; border: 1px solid #111 !important; border-collapse: collapse !important; border-spacing: 0; background: #fff;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #111 !important; padding: 12px; text-align: left; background: #0b5fab; color: #fff;\" scope=\"col\">Selection factor<\/th>\n<th style=\"border: 1px solid #111 !important; padding: 12px; text-align: left; background: #0b5fab; color: #fff;\" scope=\"col\">Gate valve<\/th>\n<th style=\"border: 1px solid #111 !important; padding: 12px; text-align: left; background: #0b5fab; color: #fff;\" scope=\"col\">Ball valve<\/th>\n<th style=\"border: 1px solid #111 !important; padding: 12px; text-align: left; background: #0b5fab; color: #fff;\" scope=\"col\">Selection meaning<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\"><strong>Operation<\/strong><\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\">Multi-turn linear movement<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\">Quarter-turn rotary movement<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\">Ball valves normally operate faster and are easier to automate<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\"><strong>Pressure loss<\/strong><\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\">Low when fully open<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\">Low with a full-bore design; higher with reduced bore<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\">Check the actual bore, not only the valve type<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\"><strong>Shutoff<\/strong><\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\">Reliable isolation with suitable wedge, seat and trim<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\">Soft seats can provide very tight shutoff; metal seats suit severe duty<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\">State the required leakage acceptance method<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\"><strong>Installation space<\/strong><\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\">Needs vertical clearance for stem and gate travel<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\">More compact above the pipeline<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\">Check actuator, gearbox and maintenance access<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\"><strong>Throttling<\/strong><\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\">Generally unsuitable for prolonged partial opening<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\">Standard isolation designs are not intended for continuous control<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top;\">Use a purpose-designed control valve when regulation is required<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\"><strong>Typical maintenance concern<\/strong><\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\">Stem packing, wedge and seat wear, and stem travel<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\">Seat damage, cavity pressure, packing and actuator alignment<\/td>\n<td style=\"border: 1px solid #111 !important; padding: 12px; vertical-align: top; background: #f7f9fc;\">Plan access and spare parts before installation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin: 0; color: #526070; font-size: 15px;\">On a phone, swipe the table left or right to view every column.<\/p>\n<\/section>\n<section>\n<h2 style=\"margin: 34px 0 12px; font-size: 29px; line-height: 1.3; color: #101828;\">Which valve has lower pressure loss?<\/h2>\n<p style=\"margin: 0 0 15px;\">A fully open gate valve and a full-bore ball valve can both provide a nearly straight flow path. The ball valve advantage disappears if a reduced-bore design is selected without considering allowable velocity and pressure drop.<\/p>\n<p style=\"margin: 0;\">For piggable pipelines, the purchaser should specify the required bore and pigging conditions. \u201cFull port\u201d should be confirmed against the referenced standard and approved drawing instead of treated as a general marketing term.<\/p>\n<\/section>\n<section id=\"choose-gate\">\n<h2 style=\"margin: 34px 0 12px; font-size: 29px; line-height: 1.3; color: #101828;\">When should you choose a gate valve?<\/h2>\n<p style=\"margin: 0 0 15px;\">Choose a gate valve when the main duty is infrequent isolation and the line should remain fully open during normal operation. Gate valves are common in steam, water, oil, power and process pipelines where low open-position resistance and established high-temperature trim options are important.<\/p>\n<p style=\"margin: 0 0 15px;\">A gate valve can also be practical at large nominal sizes where a comparable ball valve would be heavier, more expensive or require a much larger actuator. The tradeoff is slower operation and additional vertical clearance, particularly with an outside-screw-and-yoke rising stem.<\/p>\n<p style=\"margin: 0;\">For elevated pressure and temperature, a pressure-seal bonnet may be specified. The<br \/>\n<a style=\"color: #075da8; text-decoration: underline;\" href=\"https:\/\/wdlvalve.com\/product\/self-sealing-forged-steel-gate-valve\/\">WDL pressure-seal forged steel gate valve<\/a><br \/>\nis one example designed for water, steam and oil pipeline isolation.<\/p>\n<\/section>\n<section id=\"choose-ball\">\n<h2 style=\"margin: 34px 0 12px; font-size: 29px; line-height: 1.3; color: #101828;\">When should you choose a ball valve?<\/h2>\n<p style=\"margin: 0 0 15px;\">Choose a ball valve when the process needs fast operation, compact automation or tight shutoff. The 90-degree movement suits pneumatic, electric and hydraulic actuators and gives clear open or closed position indication.<\/p>\n<p style=\"margin: 0 0 15px;\">Ball valves are widely used in oil and gas, petrochemical, chemical, LNG, marine and utility systems. Floating designs are common in smaller sizes, while trunnion-mounted designs reduce operating torque in larger sizes and higher differential pressure service.<\/p>\n<p style=\"margin: 0;\">Seat selection remains decisive. Soft seats may provide very tight isolation but have defined temperature, pressure and chemical limits. Metal-seated ball valves can handle higher temperature or abrasive media, but their leakage acceptance and operating torque must be specified. Review the WDL<br \/>\n<a style=\"color: #075da8; text-decoration: underline;\" href=\"https:\/\/wdlvalve.com\/product-category\/valve-types\/ball-valves\/\">industrial ball valve range<\/a><br \/>\nand the related<br \/>\n<a style=\"color: #075da8; text-decoration: underline;\" href=\"https:\/\/wdlvalve.com\/industrial-ball-valve-selection\/\">industrial ball valve selection guide<\/a>.<\/p>\n<\/section>\n<section id=\"service\">\n<h2 style=\"margin: 34px 0 12px; font-size: 29px; line-height: 1.3; color: #101828;\">How do media and temperature affect gate valve vs ball valve selection?<\/h2>\n<p style=\"margin: 0 0 15px;\">Temperature can shift the decision toward a metal-seated gate valve or a purpose-designed metal-seated ball valve. Standard polymer ball-valve seats must remain within their pressure-temperature and chemical limits. Cryogenic ball valves need suitable materials, an extended bonnet or stem arrangement, controlled cavity pressure and project-specific testing.<\/p>\n<p style=\"margin: 0 0 15px;\">Solids also change the comparison. Particles can collect in a ball-valve cavity or damage soft seats. A conventional gate valve may experience solids packing in the body bottom or scoring across the seating surfaces. Slurry service may require a knife gate valve, severe-service ball valve or another design developed for the particle size, concentration and cycling frequency.<\/p>\n<p style=\"margin: 0;\">For corrosive media, do not select the valve by body material alone. The ball or wedge, seats, stem, packing, gaskets, bolting and any coating must be compatible with the concentration, temperature, contaminants and cleaning chemicals.<\/p>\n<\/section>\n<section>\n<h2 style=\"margin: 34px 0 12px; font-size: 29px; line-height: 1.3; color: #101828;\">Which valve is easier to automate and maintain?<\/h2>\n<p style=\"margin: 0 0 15px;\">Ball valves are generally easier to automate because the closure member moves through 90 degrees. Gate valves require multi-turn rotary input or a linear actuator with enough stroke to move the gate fully. Actuator sizing for both types must consider maximum differential pressure, seat friction, packing load, service factor and required operating time.<\/p>\n<p style=\"margin: 0 0 15px;\">Maintenance access can be more important than theoretical simplicity. A top-entry ball valve may allow internal access without removing the entire body, while a side-entry design may require pipeline removal. A bolted-bonnet gate valve provides access from above but needs clearance to withdraw the stem and gate assembly.<\/p>\n<p style=\"margin: 0;\">The purchase specification should identify recommended spare parts, special tools, lubrication requirements, stem or seat injection systems, actuator settings and the permitted field-repair scope.<\/p>\n<\/section>\n<section>\n<h2 style=\"margin: 34px 0 12px; font-size: 29px; line-height: 1.3; color: #101828;\">What standards apply to gate and ball valves?<\/h2>\n<p style=\"margin: 0 0 15px;\">The applicable standard depends on pipeline service and valve construction.<br \/>\n<a style=\"color: #075da8; text-decoration: underline;\" href=\"https:\/\/www.api.org\/products-and-services\/standards\/important-standards-announcements\/spec6d\" target=\"_blank\" rel=\"noopener\">API Specification 6D<\/a><br \/>\ncovers pipeline and piping valve requirements for valve types that include gate and ball valves. Ball-valve projects may also reference API 608, while steel gate valves commonly use standards such as API 600 or API 602 according to construction and size.<\/p>\n<p style=\"margin: 0;\">The official<br \/>\n<a style=\"color: #075da8; text-decoration: underline;\" href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/b16-34-valves-flanged-threaded-welding-end\" target=\"_blank\" rel=\"noopener\">ASME B16.34<\/a><br \/>\nscope includes pressure-temperature ratings, materials, dimensions, testing and marking for applicable valve constructions. Always state the required edition, testing standard, fire-safe requirement, fugitive-emission requirement and project additions in the purchase order.<\/p>\n<\/section>\n<section>\n<h2 style=\"margin: 34px 0 12px; font-size: 29px; line-height: 1.3; color: #101828;\">What should be included in a valve inquiry?<\/h2>\n<p style=\"margin: 0 0 15px;\">A useful inquiry allows the manufacturer to compare gate valve vs ball valve options against the same service conditions. Include the following information:<\/p>\n<ul style=\"margin: 0; padding-left: 24px;\">\n<li style=\"margin-bottom: 8px;\">Valve size, pressure class and required end connection.<\/li>\n<li style=\"margin-bottom: 8px;\">Design pressure, operating pressure and maximum differential pressure.<\/li>\n<li style=\"margin-bottom: 8px;\">Minimum, normal and maximum temperature.<\/li>\n<li style=\"margin-bottom: 8px;\">Medium, concentration, solids content and corrosion concerns.<\/li>\n<li style=\"margin-bottom: 8px;\">Body, trim, seat, packing and bolting requirements.<\/li>\n<li style=\"margin-bottom: 8px;\">Manual, pneumatic, electric or hydraulic operation.<\/li>\n<li style=\"margin-bottom: 8px;\">Required operating time and normal cycling frequency.<\/li>\n<li>Design, testing, fire-safe, emission and documentation standards.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\" aria-labelledby=\"faq-heading\">\n<h2 id=\"faq-heading\" style=\"margin: 34px 0 14px; font-size: 29px; line-height: 1.3; color: #101828;\">Frequently asked questions about gate valve vs ball valve selection<\/h2>\n<h3 style=\"margin: 22px 0 8px; font-size: 22px; color: #172033;\">Is a ball valve better than a gate valve?<\/h3>\n<p style=\"margin: 0 0 15px;\">A ball valve is usually better for fast operation, compact automation and tight soft-seat shutoff. A gate valve may be better for large sizes, infrequent full-bore isolation and high-temperature service. The operating conditions decide which design is better.<\/p>\n<h3 style=\"margin: 22px 0 8px; font-size: 22px; color: #172033;\">Can gate valves and ball valves be used for flow control?<\/h3>\n<p style=\"margin: 0 0 15px;\">Standard isolation gate valves and ball valves should not be assumed suitable for continuous throttling. Partial opening can cause vibration, erosion, seat damage or unstable control. Use a valve and trim specifically designed for regulation when flow control is required.<\/p>\n<h3 style=\"margin: 22px 0 8px; font-size: 22px; color: #172033;\">Which valve closes faster?<\/h3>\n<p style=\"margin: 0 0 15px;\">A ball valve normally closes faster because it requires only a quarter turn. Fast closing can increase surge or water-hammer risk, so actuator speed may need to be controlled.<\/p>\n<h3 style=\"margin: 22px 0 8px; font-size: 22px; color: #172033;\">Which valve is better for high temperature?<\/h3>\n<p style=\"margin: 0 0 15px;\">Metal-seated gate valves are widely used in high-temperature service, but purpose-designed metal-seated ball valves can also be suitable. Verify the pressure-temperature rating of the body, seats, packing, gaskets and bolting.<\/p>\n<h3 style=\"margin: 22px 0 8px; font-size: 22px; color: #172033;\">Which valve is better for buried pipelines?<\/h3>\n<p style=\"margin: 0;\">Both types can be engineered for buried service. Ball valves are common in transmission pipelines because of quarter-turn operation and trunnion-mounted options. Buried gate valves remain common in water systems. Extension stems, coatings, sealing, drainage and access must match the installation.<\/p>\n<\/section>\n<section style=\"margin: 36px 0 26px; padding: 24px; border: 1px solid #0b5fab; background: #f3f8fc;\">\n<h2 style=\"margin: 0 0 10px; font-size: 26px; color: #101828;\">Need help choosing between a gate valve and ball valve?<\/h2>\n<p style=\"margin: 0 0 16px;\">WDL Valve can compare valve type, material, seat, pressure class, end connection and actuation against your project conditions.<\/p>\n<p style=\"margin: 0;\"><a style=\"display: inline-block; padding: 11px 20px; background: #0b5fab; color: #fff; text-decoration: none; border-radius: 3px; font-weight: bold;\" href=\"https:\/\/wdlvalve.com\/contact-us\/\">Discuss Your Valve Application<\/a><\/p>\n<\/section>\n<footer style=\"margin-top: 34px; padding-top: 20px; border-top: 1px solid #cbd5df;\">\n<p style=\"margin: 0 0 4px;\"><strong>Author: Wong WP<\/strong><\/p>\n<p style=\"margin: 0 0 4px;\">Sales Manager, Xiamen WDL Valve Co., Ltd.<\/p>\n<p style=\"margin: 0;\">Technical focus: industrial valve materials, operating conditions and project specification review.<\/p>\n<\/footer>\n<\/article>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Article\",\n      \"headline\": \"Gate Valve vs Ball Valve: How to Choose for Industrial Isolation\",\n      \"description\": \"A practical comparison of gate valves and ball valves for industrial isolation service.\",\n      \"dateModified\": \"2026-10-09\",\n      \"author\": {\n        \"@type\": \"Person\",\n        \"name\": \"Wong WP\",\n        \"jobTitle\": \"Sales Manager\",\n        \"worksFor\": {\n          \"@type\": \"Organization\",\n          \"name\": \"Xiamen WDL Valve Co., Ltd.\",\n          \"url\": \"https:\/\/wdlvalve.com\/\"\n        }\n      },\n      \"publisher\": {\n        \"@type\": \"Organization\",\n        \"name\": \"Xiamen WDL Valve Co., Ltd.\",\n        \"url\": \"https:\/\/wdlvalve.com\/\"\n      },\n      \"mainEntityOfPage\": \"https:\/\/wdlvalve.com\/gate-valve-vs-ball-valve\/\"\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Is a ball valve better than a gate valve?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"A ball valve is usually better for fast operation, compact automation and tight soft-seat shutoff. A gate valve may be better for large sizes, infrequent full-bore isolation and high-temperature service.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Can gate valves and ball valves be used for flow control?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Standard isolation gate valves and ball valves should not be assumed suitable for continuous throttling. Use a valve and trim specifically designed for regulation.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Which valve closes faster?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"A ball valve normally closes faster because it requires only a quarter turn. Closing speed may need to be controlled to reduce surge or water-hammer risk.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Which valve is better for high temperature?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Metal-seated gate valves are widely used at high temperature, but purpose-designed metal-seated ball valves can also be suitable.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Which valve is better for buried pipelines?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Both types can be engineered for buried service. Ball valves are common in transmission pipelines, while buried gate valves remain common in water systems.\"\n          }\n        }\n      ]\n    }\n  ]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Leitfaden zur Auswahl von Industriearmaturen \u00b7 \u00dcberarbeitet im Oktober 2026 Die Wahl zwischen Absperrschieber und Kugelhahn h\u00e4ngt von den Anforderungen an die Absperrleistung, der Bet\u00e4tigungsgeschwindigkeit, dem Druckverlust, dem Medium, der Temperatur, dem Einbauraum und dem Wartungsplan ab. Ein Absperrschieber wird h\u00e4ufig f\u00fcr die Absperrung mit vollem Durchgang in gro\u00dfen Rohrleitungen und im Hochtemperaturbereich bevorzugt, w\u00e4hrend ein Kugelhahn in der Regel besser geeignet ist, wenn eine schnelle Vierteldrehung\u2026<\/p>","protected":false},"author":1,"featured_media":788,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"default","_kad_post_title":"default","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[52],"tags":[],"class_list":["post-1355","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/posts\/1355","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/comments?post=1355"}],"version-history":[{"count":1,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/posts\/1355\/revisions"}],"predecessor-version":[{"id":1356,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/posts\/1355\/revisions\/1356"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/media\/788"}],"wp:attachment":[{"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/media?parent=1355"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/categories?post=1355"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/tags?post=1355"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}