{"id":929,"date":"2026-09-16T09:10:14","date_gmt":"2026-09-16T09:10:14","guid":{"rendered":"https:\/\/wdlvalve.com\/?post_type=product&#038;p=929"},"modified":"2026-09-17T03:15:36","modified_gmt":"2026-09-17T03:15:36","slug":"zirconium-gate-valve","status":"publish","type":"product","link":"https:\/\/wdlvalve.com\/de\/product\/zirconium-gate-valve\/","title":{"rendered":"Zirkonium-Absperrschieber"},"content":{"rendered":"<article class=\"wdl-product-content\">\n<section>\n<h2>Zirkonium-Absperrschieber<\/h2>\n<p><strong>WDL Zirconium Gate Valve<\/strong> provides full-bore on-off isolation with low pressure loss when open for process systems that need resistance to many strong acids and corrosive chemical mixtures. Zirconium is used for severe acid duties where stainless steels and many nickel alloys cannot provide an acceptable corrosion rate.<\/p>\n<\/section>\n<section>\n<h2>Gestaltungsm\u00f6glichkeiten<\/h2>\n<div style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 18px 0;\">\n<table style=\"width: 100%; min-width: 680px; border-collapse: collapse; border: 1px solid #333;\">\n<tbody>\n<tr>\n<th style=\"border: 1px solid #333; padding: 9px; text-align: left;\">Artikel<\/th>\n<th style=\"border: 1px solid #333; padding: 9px; text-align: left;\">Verf\u00fcgbare Spezifikationen<\/th>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">Material<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">Zirconium 702, 705 or project-specified grade<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">Funktion<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">full-bore on-off isolation with low pressure loss when open<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">Verbindungen<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">Flanged or butt-welded<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">Betrieb<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">Handwheel, gearbox, pneumatic or electric actuator<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">Auslegungsgrundlage<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">API 600, API 603, API 6D or ASME B16.34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<section>\n<h2>Typische Anwendungsbereiche<\/h2>\n<ul>\n<li>Acetic and formic acid processing<\/li>\n<li>Selected sulfuric acid systems<\/li>\n<li>Chemical reactors and transfer lines<\/li>\n<li>Main process isolation<\/li>\n<li>Full-bore pipeline service<\/li>\n<\/ul>\n<\/section>\n<section>\n<h2>Hinweise zur Auswahl<\/h2>\n<p>Fluoride-containing media, hydrofluoric acid and some oxidizing halides require special review because they can attack zirconium.<\/p>\n<p>Gate valves are normally selected for isolation rather than continuous throttling; confirm wedge, seat and stem design.<\/p>\n<\/section>\n<section>\n<h2>H\u00e4ufig gestellte Fragen<\/h2>\n<h3>Why select Zirconium for this gate valve?<\/h3>\n<p>Zirconium is used for severe acid duties where stainless steels and many nickel alloys cannot provide an acceptable corrosion rate. Final suitability depends on the complete process conditions and the selected valve trim.<\/p>\n<h3>Welche Informationen werden f\u00fcr die Auswahl ben\u00f6tigt?<\/h3>\n<p>Geben Sie die Gr\u00f6\u00dfe, die Druckstufe, die Zusammensetzung des Mediums, die Konzentration, die Temperatur, die Anschlussnorm, die Betriebsart und die ben\u00f6tigte Menge an.<\/p>\n<\/section>\n<p>Senden Sie das Prozessdatenblatt an WDL zur Materialpr\u00fcfung, Ma\u00dfbest\u00e4tigung und Angebotserstellung.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>WDL Zirconium Gate Valve provides full-bore on-off isolation with low pressure loss when open for acetic and formic acid processing and selected sulfuric acid systems. Connections, trim and operation are selected to the project conditions.<\/p>","protected":false},"featured_media":774,"comment_status":"open","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"product_brand":[72],"product_cat":[35,32,31,46],"product_tag":[83,103,84,82,164],"class_list":["post-929","product","type-product","status-publish","has-post-thumbnail","product_brand-wdl-valve","product_cat-gate-valves","product_cat-valve-materials","product_cat-valve-types","product_cat-titanium-zirconium-valves","product_tag-acetic-and-formic-acid-processing","product_tag-gate-valve","product_tag-selected-sulfuric-acid-systems","product_tag-zirconium","product_tag-zirconium-gate-valve","first","instock","shipping-taxable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/product\/929","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/comments?post=929"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/media\/774"}],"wp:attachment":[{"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/media?parent=929"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/product_brand?post=929"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/product_cat?post=929"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wdlvalve.com\/de\/wp-json\/wp\/v2\/product_tag?post=929"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}