{"id":905,"date":"2026-09-16T09:10:08","date_gmt":"2026-09-16T09:10:08","guid":{"rendered":"https:\/\/wdlvalve.com\/?post_type=product&#038;p=905"},"modified":"2026-09-17T03:55:02","modified_gmt":"2026-09-17T03:55:02","slug":"monel-gate-valve","status":"publish","type":"product","link":"https:\/\/wdlvalve.com\/ru\/product\/monel-gate-valve\/","title":{"rendered":"\u0417\u0430\u0434\u0432\u0438\u0436\u043a\u0430 \u0438\u0437 \u043c\u043e\u043d\u0435\u043b\u044f"},"content":{"rendered":"<article class=\"wdl-product-content\">\n<section>\n<h2>\u0417\u0430\u0434\u0432\u0438\u0436\u043a\u0430 \u0438\u0437 \u043c\u043e\u043d\u0435\u043b\u044f<\/h2>\n<p><strong>WDL Monel Gate Valve<\/strong> provides full-bore on-off isolation with low pressure loss when open for process systems that need resistance to hydrofluoric acid, seawater and selected reducing media. Monel 400 is a nickel-copper alloy used for controlled hydrofluoric acid, marine and reducing chemical duties.<\/p>\n<\/section>\n<section>\n<h2>\u0412\u0430\u0440\u0438\u0430\u043d\u0442\u044b \u0434\u0438\u0437\u0430\u0439\u043d\u0430<\/h2>\n<div style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 18px 0;\">\n<table style=\"width: 100%; min-width: 680px; border-collapse: collapse; border: 1px solid #333;\">\n<tbody>\n<tr>\n<th style=\"border: 1px solid #333; padding: 9px; text-align: left;\">\u041f\u0443\u043d\u043a\u0442<\/th>\n<th style=\"border: 1px solid #333; padding: 9px; text-align: left;\">\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u044b\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/th>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">\u041c\u0430\u0442\u0435\u0440\u0438\u0430\u043b<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">\u041c\u043e\u043d\u0435\u043b\u044c 400 \/ UNS N04400 \u0441 \u043e\u043f\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u043e\u0439 \u043e\u0442\u0434\u0435\u043b\u043a\u043e\u0439 K-500<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">full-bore on-off isolation with low pressure loss when open<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">\u0421\u0432\u044f\u0437\u0438<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">Flanged or butt-welded<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">\u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">Handwheel, gearbox, pneumatic or electric actuator<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">\u041f\u0440\u043e\u0435\u043a\u0442\u043d\u044b\u0435 \u0443\u0441\u043b\u043e\u0432\u0438\u044f<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">API 600, API 603, API 6D or ASME B16.34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<section>\n<h2>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/h2>\n<ul>\n<li>\u041e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0430 \u0444\u0442\u043e\u0440\u0438\u0441\u0442\u043e\u0432\u043e\u0434\u043e\u0440\u043e\u0434\u043d\u043e\u0439 \u043a\u0438\u0441\u043b\u043e\u0442\u043e\u0439<\/li>\n<li>\u041c\u043e\u0440\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0438 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u043c\u043e\u0440\u0441\u043a\u043e\u0439 \u0432\u043e\u0434\u044b<\/li>\n<li>\u0420\u0430\u0431\u043e\u0442\u0430 \u0441 \u0440\u0430\u0441\u0441\u043e\u043b\u043e\u043c \u0438 \u0441\u043e\u043b\u044c\u044e<\/li>\n<li>Main process isolation<\/li>\n<li>Full-bore pipeline service<\/li>\n<\/ul>\n<\/section>\n<section>\n<h2>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u044f \u043f\u043e \u0432\u044b\u0431\u043e\u0440\u0443<\/h2>\n<p>\u0410\u044d\u0440\u0430\u0446\u0438\u044f, \u043e\u043a\u0438\u0441\u043b\u044f\u044e\u0449\u0438\u0435 \u0441\u043e\u043b\u0438, \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430 \u0438 \u043f\u0440\u0438\u043c\u0435\u0441\u0438 \u043c\u043e\u0433\u0443\u0442 \u0432\u043b\u0438\u044f\u0442\u044c \u043d\u0430 \u043a\u043e\u0440\u0440\u043e\u0437\u0438\u043e\u043d\u043d\u044b\u0435 \u0441\u0432\u043e\u0439\u0441\u0442\u0432\u0430 \u043c\u043e\u043d\u0435\u043b\u044f 400 \u0438 \u0434\u043e\u043b\u0436\u043d\u044b \u0443\u0447\u0438\u0442\u044b\u0432\u0430\u0442\u044c\u0441\u044f \u043f\u0440\u0438 \u043e\u0446\u0435\u043d\u043a\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u0430.<\/p>\n<p>Gate valves are normally selected for isolation rather than continuous throttling; confirm wedge, seat and stem design.<\/p>\n<\/section>\n<section>\n<h2>\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n<h3>Why select Monel 400 for this gate valve?<\/h3>\n<p>\u041c\u043e\u043d\u0435\u043b\u044c 400 \u2014 \u044d\u0442\u043e \u043d\u0438\u043a\u0435\u043b\u044c-\u043c\u0435\u0434\u043d\u044b\u0439 \u0441\u043f\u043b\u0430\u0432, \u043f\u0440\u0438\u043c\u0435\u043d\u044f\u0435\u043c\u044b\u0439 \u0432 \u0443\u0441\u043b\u043e\u0432\u0438\u044f\u0445 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u043e\u0433\u043e \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u044f \u0444\u0442\u043e\u0440\u0438\u0441\u0442\u043e\u0432\u043e\u0434\u043e\u0440\u043e\u0434\u043d\u043e\u0439 \u043a\u0438\u0441\u043b\u043e\u0442\u044b, \u043c\u043e\u0440\u0441\u043a\u043e\u0439 \u0441\u0440\u0435\u0434\u044b \u0438 \u0432\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0445 \u0445\u0438\u043c\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0432\u0435\u0449\u0435\u0441\u0442\u0432. \u041e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u0430\u044f \u043f\u0440\u0438\u0433\u043e\u0434\u043d\u043e\u0441\u0442\u044c \u0437\u0430\u0432\u0438\u0441\u0438\u0442 \u043e\u0442 \u0432\u0441\u0435\u0445 \u0443\u0441\u043b\u043e\u0432\u0438\u0439 \u0442\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u0430 \u0438 \u0432\u044b\u0431\u0440\u0430\u043d\u043d\u043e\u0439 \u0432\u043d\u0443\u0442\u0440\u0435\u043d\u043d\u0435\u0439 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438 \u043a\u043b\u0430\u043f\u0430\u043d\u0430.<\/p>\n<h3>\u041a\u0430\u043a\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u0430 \u0434\u043b\u044f \u043e\u0442\u0431\u043e\u0440\u0430?<\/h3>\n<p>\u0423\u043a\u0430\u0436\u0438\u0442\u0435 \u0440\u0430\u0437\u043c\u0435\u0440, \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0434\u0430\u0432\u043b\u0435\u043d\u0438\u0435, \u0441\u043e\u0441\u0442\u0430\u0432 \u0441\u0440\u0435\u0434\u044b, \u043a\u043e\u043d\u0446\u0435\u043d\u0442\u0440\u0430\u0446\u0438\u044e, \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0443, \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f, \u0441\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0438 \u043d\u0435\u043e\u0431\u0445\u043e\u0434\u0438\u043c\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e.<\/p>\n<\/section>\n<p>\u041e\u0442\u043f\u0440\u0430\u0432\u044c\u0442\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u0430 \u0432 \u043a\u043e\u043c\u043f\u0430\u043d\u0438\u044e WDL \u0434\u043b\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432, \u043f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0438\u044f \u0440\u0430\u0437\u043c\u0435\u0440\u043e\u0432 \u0438 \u043f\u043e\u043b\u0443\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043c\u043c\u0435\u0440\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043f\u0440\u0435\u0434\u043b\u043e\u0436\u0435\u043d\u0438\u044f.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>WDL Monel Gate Valve provides full-bore on-off isolation with low pressure loss when open for hydrofluoric acid processing and marine and seawater systems. Connections, trim and operation are selected to the project conditions.<\/p>","protected":false},"featured_media":711,"comment_status":"open","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"product_brand":[72],"product_cat":[35,32,31,66],"product_tag":[103,135,136,134,140],"class_list":["post-905","product","type-product","status-publish","has-post-thumbnail","product_brand-wdl-valve","product_cat-gate-valves","product_cat-valve-materials","product_cat-valve-types","product_cat-monel-valves","product_tag-gate-valve","product_tag-hydrofluoric-acid-processing","product_tag-marine-and-seawater-systems","product_tag-monel-400","product_tag-monel-gate-valve","first","instock","shipping-taxable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/wdlvalve.com\/ru\/wp-json\/wp\/v2\/product\/905","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wdlvalve.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/wdlvalve.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/wdlvalve.com\/ru\/wp-json\/wp\/v2\/comments?post=905"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wdlvalve.com\/ru\/wp-json\/wp\/v2\/media\/711"}],"wp:attachment":[{"href":"https:\/\/wdlvalve.com\/ru\/wp-json\/wp\/v2\/media?parent=905"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/wdlvalve.com\/ru\/wp-json\/wp\/v2\/product_brand?post=905"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wdlvalve.com\/ru\/wp-json\/wp\/v2\/product_cat?post=905"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wdlvalve.com\/ru\/wp-json\/wp\/v2\/product_tag?post=905"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}