{"id":902,"date":"2026-09-16T09:10:08","date_gmt":"2026-09-16T09:10:08","guid":{"rendered":"https:\/\/wdlvalve.com\/?post_type=product&#038;p=902"},"modified":"2026-09-17T03:51:31","modified_gmt":"2026-09-17T03:51:31","slug":"monel-check-valve","status":"publish","type":"product","link":"https:\/\/wdlvalve.com\/vi\/product\/monel-check-valve\/","title":{"rendered":"Van m\u1ed9t chi\u1ec1u Monel"},"content":{"rendered":"<article class=\"wdl-product-content\">\n<section>\n<h2>Van m\u1ed9t chi\u1ec1u Monel<\/h2>\n<p><strong>WDL Monel Check Valve<\/strong> provides automatic prevention of reverse flow for process systems that need resistance to hydrofluoric acid, seawater and selected reducing media. Monel 400 is a nickel-copper alloy used for controlled hydrofluoric acid, marine and reducing chemical duties.<\/p>\n<\/section>\n<section>\n<h2>C\u00e1c t\u00f9y ch\u1ecdn thi\u1ebft k\u1ebf<\/h2>\n<div style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 18px 0;\">\n<table style=\"width: 100%; min-width: 680px; border-collapse: collapse; border: 1px solid #333;\">\n<tbody>\n<tr>\n<th style=\"border: 1px solid #333; padding: 9px; text-align: left;\">M\u1eb7t h\u00e0ng<\/th>\n<th style=\"border: 1px solid #333; padding: 9px; text-align: left;\">Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt hi\u1ec7n c\u00f3<\/th>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">Ch\u1ea5t li\u1ec7u<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">Monel 400 \/ UNS N04400 v\u1edbi b\u1ed9 ph\u1ee5 ki\u1ec7n K-500 (t\u00f9y ch\u1ecdn)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">Ch\u1ee9c n\u0103ng<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">automatic prevention of reverse flow<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">K\u1ebft n\u1ed1i<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">Wafer, lugged, flanged or butt-welded<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">Ho\u1ea1t \u0111\u1ed9ng<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">Self-actuated swing, lift, piston or dual-plate mechanism<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #333; padding: 9px;\">C\u01a1 s\u1edf thi\u1ebft k\u1ebf<\/td>\n<td style=\"border: 1px solid #333; padding: 9px;\">API 594, BS 1868, API 598 or project standard<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<section>\n<h2>C\u00e1c \u1ee9ng d\u1ee5ng \u0111i\u1ec3n h\u00ecnh<\/h2>\n<ul>\n<li>Quy tr\u00ecnh x\u1eed l\u00fd b\u1eb1ng axit hydrofluoric<\/li>\n<li>H\u1ec7 th\u1ed1ng h\u00e0ng h\u1ea3i v\u00e0 n\u01b0\u1edbc bi\u1ec3n<\/li>\n<li>X\u1eed l\u00fd n\u01b0\u1edbc mu\u1ed1i v\u00e0 mu\u1ed1i<\/li>\n<li>Pump discharge protection<\/li>\n<li>Backflow prevention in process lines<\/li>\n<\/ul>\n<\/section>\n<section>\n<h2>Ghi ch\u00fa v\u1ec1 vi\u1ec7c l\u1ef1a ch\u1ecdn<\/h2>\n<p>Qu\u00e1 tr\u00ecnh s\u1ee5c kh\u00ed, mu\u1ed1i oxy h\u00f3a, nhi\u1ec7t \u0111\u1ed9 v\u00e0 c\u00e1c t\u1ea1p ch\u1ea5t c\u00f3 th\u1ec3 l\u00e0m thay \u0111\u1ed5i t\u00ednh ch\u1ea5t \u0103n m\u00f2n c\u1ee7a Monel 400 v\u00e0 ph\u1ea3i \u0111\u01b0\u1ee3c \u0111\u01b0a v\u00e0o qu\u00e1 tr\u00ecnh \u0111\u00e1nh gi\u00e1 v\u1eadt li\u1ec7u.<\/p>\n<p>Confirm installation direction, minimum flow, cracking pressure, slam risk and allowable pressure drop.<\/p>\n<\/section>\n<section>\n<h2>C\u00e1c c\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3>Why select Monel 400 for this check valve?<\/h3>\n<p>Monel 400 l\u00e0 m\u1ed9t h\u1ee3p kim niken-\u0111\u1ed3ng \u0111\u01b0\u1ee3c s\u1eed d\u1ee5ng trong c\u00e1c \u1ee9ng d\u1ee5ng li\u00ean quan \u0111\u1ebfn axit hydrofluoric \u1edf n\u1ed3ng \u0111\u1ed9 \u0111\u01b0\u1ee3c ki\u1ec3m so\u00e1t, m\u00f4i tr\u01b0\u1eddng bi\u1ec3n v\u00e0 c\u00e1c h\u00f3a ch\u1ea5t kh\u1eed. T\u00ednh ph\u00f9 h\u1ee3p cu\u1ed1i c\u00f9ng ph\u1ee5 thu\u1ed9c v\u00e0o to\u00e0n b\u1ed9 \u0111i\u1ec1u ki\u1ec7n qu\u00e1 tr\u00ecnh v\u00e0 b\u1ed9 ph\u1eadn b\u00ean trong van \u0111\u01b0\u1ee3c l\u1ef1a ch\u1ecdn.<\/p>\n<h3>C\u1ea7n nh\u1eefng th\u00f4ng tin n\u00e0o \u0111\u1ec3 ti\u1ebfn h\u00e0nh l\u1ef1a ch\u1ecdn?<\/h3>\n<p>Vui l\u00f2ng cung c\u1ea5p th\u00f4ng tin v\u1ec1 k\u00edch th\u01b0\u1edbc, m\u1ee9c \u00e1p su\u1ea5t \u0111\u1ecbnh m\u1ee9c, th\u00e0nh ph\u1ea7n m\u00f4i tr\u01b0\u1eddng, n\u1ed3ng \u0111\u1ed9, nhi\u1ec7t \u0111\u1ed9, ti\u00eau chu\u1ea9n k\u1ebft n\u1ed1i, ph\u01b0\u01a1ng th\u1ee9c v\u1eadn h\u00e0nh v\u00e0 s\u1ed1 l\u01b0\u1ee3ng c\u1ea7n thi\u1ebft.<\/p>\n<\/section>\n<p>Vui l\u00f2ng g\u1eedi b\u1ea3ng th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt quy tr\u00ecnh cho WDL \u0111\u1ec3 xem x\u00e9t v\u1eadt li\u1ec7u, x\u00e1c nh\u1eadn k\u00edch th\u01b0\u1edbc v\u00e0 nh\u1eadn b\u00e1o gi\u00e1.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Van m\u1ed9t chi\u1ec1u WDL Monel c\u00f3 ch\u1ee9c n\u0103ng t\u1ef1 \u0111\u1ed9ng ng\u0103n ch\u1eb7n d\u00f2ng ch\u1ea3y ng\u01b0\u1ee3c trong c\u00e1c h\u1ec7 th\u1ed1ng x\u1eed l\u00fd axit hydrofluoric c\u0169ng nh\u01b0 c\u00e1c h\u1ec7 th\u1ed1ng h\u00e0ng h\u1ea3i v\u00e0 n\u01b0\u1edbc bi\u1ec3n. C\u00e1c \u0111\u1ea7u n\u1ed1i, b\u1ed9 ph\u1eadn b\u00ean trong v\u00e0 c\u01a1 ch\u1ebf v\u1eadn h\u00e0nh \u0111\u01b0\u1ee3c l\u1ef1a ch\u1ecdn ph\u00f9 h\u1ee3p v\u1edbi \u0111i\u1ec1u ki\u1ec7n c\u1ee5 th\u1ec3 c\u1ee7a d\u1ef1 \u00e1n.<\/p>","protected":false},"featured_media":703,"comment_status":"open","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"product_brand":[72],"product_cat":[37,32,31,66],"product_tag":[121,135,136,134,137],"class_list":["post-902","product","type-product","status-publish","has-post-thumbnail","product_brand-wdl-valve","product_cat-check-valves","product_cat-valve-materials","product_cat-valve-types","product_cat-monel-valves","product_tag-check-valve","product_tag-hydrofluoric-acid-processing","product_tag-marine-and-seawater-systems","product_tag-monel-400","product_tag-monel-check-valve","first","instock","shipping-taxable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/wdlvalve.com\/vi\/wp-json\/wp\/v2\/product\/902","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wdlvalve.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/wdlvalve.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/wdlvalve.com\/vi\/wp-json\/wp\/v2\/comments?post=902"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wdlvalve.com\/vi\/wp-json\/wp\/v2\/media\/703"}],"wp:attachment":[{"href":"https:\/\/wdlvalve.com\/vi\/wp-json\/wp\/v2\/media?parent=902"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/wdlvalve.com\/vi\/wp-json\/wp\/v2\/product_brand?post=902"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wdlvalve.com\/vi\/wp-json\/wp\/v2\/product_cat?post=902"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wdlvalve.com\/vi\/wp-json\/wp\/v2\/product_tag?post=902"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}